The GI MARS is a next-generation anesthesia workstation from Gulati Industries,engineered for accuracy, reliability, and complete clinical control. Designed for adult and pediatric patients, it combines intelligent electronic control with pneumatic precision. Its built-in pre-check functions, ergonomic interface, and comprehensive monitoring make it the preferred choice for modern operation theatres.
Highlights
Dual Control System: Pneumatically driven, electronically controlled
Operating Modes: Semi-open, Semi-closed, and Closed
Vaporizer Mounting: Selectatec system with dual mounting capability
Included Vaporizer: One vaporizer supplied — choice of Isoflurane / Sevoflurane / Halothane
Included Vaporizer: One vaporizer included — choice of Isoflurane, Sevoflurane, or Halothane
Power Input: 100–240 V, 50/60 Hz
Built-in Intelligence: Real-time detection of Pressure, Loops, RR, Tidal Volume, and Compliance
System Self-Checks: Pre-test features include sensor calibration, circuit leak test, and compliance verification
Display: 10.1" full-color LCD screen
Ventilation Modes: VCV, PCV, SIMV, AC, BAG, and Standby
Tidal Volume Range: 20 – 1500 mL
Respiratory Rate: 1 – 100 BPM (1–40 BPM under SIMV)
I:E Ratio: 4:1 – 1:8
Pressure Range: 5 – 60 cmH₂O
PEEP: 3 – 30 cmH₂O
Ptrigger Sensitivity: –20 to 0 cmH₂O
Pressure Limit: 20 – 60 mBar
Waveforms: Pressure–Time, Flow–Time, Volume–Time
Loops: Pressure–Volume, Volume–Flow, Flow–Pressure
Monitoring Parameters: Tidal Volume, Minute Volume, RR, FiO₂, PEEP, Pmax, Pmean, Cst
Alarm System: o High/Low Pressure, RR, Minute Volume, and FiO₂
o Low Battery, FiO₂ Deviation, Driving Gas Failure
Power Supply: 110–240 V AC, 50/60 Hz
Driving Gas Input: 4 Bar Pressure
Battery Backup: Up to 180 minutes
Sensor Type: Proximal sensor at patient Y-piece
Patient Category: Adult & Pediatric
Configuration: 5-Tube Cascade Flowmeter
O₂ Flow Range: 0.1–1 L/min (fine), 1–15 L/min (coarse)
N₂O Flow Range: 0.1–1 L/min (fine), 1–15 L/min (coarse)
Air Flow Range: 0.1–15 L/min
Safety Feature: O₂–N₂O Hypoxic Guard System
Oxygen Flush: 25–75 L/min
O₂ Supply Pressure: 0.25 – 0.65 MPa
N₂O Supply Pressure: 0.25 – 0.65 MPa
Air Supply Pressure: 0.25 – 0.65 MPa
Type: Integrated circle absorber with APL valve
CO₂ Absorber Volume: 2 L large-capacity absorber
Mode Selection: One-touch switch for Bag/Vent function
Bellows Adjustment: No required for Adult–Pediatric transition
Cabinet Material: Reinforced ABS body with metallic frame support
Pipeline Attachments: For O₂, N₂O, and Air
Cylinder Yokes: Independent yokes for O₂ and N₂O cylinders
Vaporizer Mounting Bar: Selectatec system with dual vaporizer capacity
ACGO Outlet: Compatible with Bain circuit connection
AGSS (Anesthetic Gas Scavenging System)
EtCO₂ Monitoring Module