Overview
The GI Anesthesia Workstation Model REWA is a high-precision, pneumatically driven and
electronically controlled anesthesia delivery system designed for adult and pediatric use. It
provides advanced monitoring, real-time loop detection, and flexible system configurations to
ensure safety, reliability, and operational efficiency in clinical environments.
Key Features
Application: Adult & Pediatric
Drive Mode: Pneumatically driven, electronically controlled
Operating Mode: Semi-open, Semi-closed, and Closed system
Anesthetic Vaporizer: Selectatec mounting system with dual vaporizer provision
Included Vaporizer: One vaporizer included — choice of Isoflurane, Sevoflurane, or Halothane
Power Supply: 100–240 V AC, 50/60 Hz
Additional Functions: Real-time detection for Pressure, Loops, Respiratory Rate, Tidal Volume, and Compliance
Display: 10.1 & high-resolution LCD screen
Ventilation Modes: VCV, SIMV, AC, BAG, and Standby
Tidal Volume: 20 – 1500 mL
Respiratory Rate: 1 – 100 BPM (1–40 BPM under SIMV)
I:E Ratio: 4:1 – 1:8
Pressure Range: 5 – 60 cmH₂O
PEEP: 3 – 30 cmH₂O
Pressure Limit: 20 – 60 mBar
Ptrigger Sensitivity: –20 to 0 cmH₂O
Waveforms Displayed: Pressure–Time, Flow–Time, Volume–Time
Loops Displayed: Pressure–Volume, Volume–Flow, Flow–Pressure
Monitoring Parameters: Tidal Volume, Minute Volume, RR, FiO₂, PEEP, Pmax, Pmean, Cdyn
Power Input: 110–240 V AC, 50/60 Hz
Driving Gas Input: 4 Bar
Battery Backup: Up to 180 minutes
Sensor Type: Proximal sensor at patient Y-piece
Patient Category: Adult & Pediatric
Alarm System: o High/Low Pressure, RR, Minute Volume, and FiO₂
o Low Battery, FiO₂ Deviation, Driving Gas Failure
Type: 5-Tube Cascade Flowmeter
O₂ Flow Range: 0.1–1 L/min (fine), 1–15 L/min (coarse)
N₂O Flow Range: 0.1–1 L/min (fine), 1–15 L/min (coarse)
Air Flow Range: 0.1–15 L/min
Safety Mechanisms: O₂–N₂O Hypoxic Guard System
Oxygen Flush Flow: 25–75 L/min
O₂ Pressure: 0.25 – 0.65 MPa
N₂O Pressure: 0.25 – 0.65 MPa
Air Pressure: 0.25 – 0.65 MPa
System Type: Integrated circle absorber with APL valve
CO₂ Absorber Volume: 2 L large-capacity canister
Mode Selection: Single switch for Bag/Vent operation
Bellows Change: Not required for Adult–Pediatric transition
Body Material: High-strength ABS enclosure
Pipeline Connections: O₂, N₂O, and Air
Cylinder Yokes: For O₂ and N₂O cylinders
Vaporizer Mounting: Selectatec bar with dual mounting provision
ACGO Port: Compatible with Bain circuit connection
AGSS (Anesthetic Gas Scavenging System)
Auxiliary Oxygen Outlet (optional)
Copyrights © Gulati Industries All rights reserved.